Footings and foundations

Commercial Footings Contractor Serving Brisbane and South East Queensland

A building is only as good as what it stands on. Footing failures don’t surface during construction. They surface years later when the structure above starts to move.

Numerous

Commercial footing packages delivered in SEQ

15+

Years civil and concrete experience

Zero

Lost Time Injuries vs industry average of 5.2 per million hours (Safe Work Australia, 2024)

AS 3600 & AS 2870

Compliant delivery across commercial and interface scopes

About this service

The Most Expensive Concrete on Any Commercial Project Is the Footing That Was Done Wrong

Reinforced concrete foundation under construction with steel rebar and formwork.

Structural footings are the foundation of everything built above them. Pad footings transfer column loads to the ground. Strip footings distribute wall loads across a bearing area. Pier footings reach deeper bearing strata where surface soils cannot carry the required load. Each type is designed by a structural engineer based on soil conditions, founding depth, and the loads the structure will impose. None of that design work matters if the footing is not built to the drawing.

The consequences of footing failures are not immediate. A footing built at the wrong depth, with insufficient reinforcement cover, or without the correct starter bar placement will carry the structure for months or years before problems emerge. By then, the building is occupied, fitout is complete, and remediation means excavating around live structural elements. Structural remediation at that stage can cost up to 10 times the original footing value. The cost is not the footing. The cost is everything above it.

SEQ projects add a specific layer of complexity. The region commonly encounters Class M to H1 reactive clay soils, which require founding depth verification against the geotechnical report before any footing is poured. Where site conditions differ from what the geotechnical investigation assumed, the structural engineer needs to be consulted before work proceeds. QCG manages this as a standard part of every commercial footing scope, not as an escalation.

QCG delivers commercial footings strictly to the structural drawings, with hold point inspections before concrete is placed and QA documentation that confirms what was built matches what was designed.

Types of commercial footings

Commercial Footing Types QCG Delivers

The following table outlines the main types of commercial footings, their typical applications, and the key design considerations for each. Footing type and specification for any project is determined by the structural engineer. QCG delivers to the structural drawings provided.

Field

Standard Concreter

CAPABILITY

Labour only

QA DOCUMENTATION

Not available

PROJECT MANAGEMENT

No program management

RPEQ ENGINEERING

Not available

PUBLIC LIABILITY

Typically $5M minimum

RIGHT FOR

Small residential only

Field

QCG

CAPABILITY

Labour + engineering systems + program certainty

QA DOCUMENTATION

Full QA docs, ITPs & SWMS on everyjob

PROJECT MANAGEMENT

Director-level management on every job

RPEQ ENGINEERING

RPEQ engineering partnership

PUBLIC LIABILITY

$20M on every job

RIGHT FOR

Mid-tier commercial, civil & residential

Field

Standard Concreter

CAPABILITY

Full systems and documentation

QA DOCUMENTATION

Built for $100M+ projects

PROJECT MANAGEMENT

Management layers, no direct line

RPEQ ENGINEERING

In-house

PUBLIC LIABILITY

$20M+

RIGHT FOR

Major infrastructure only

Footing type
Typical application
Key design consideration
Pad footing
Isolated column bases, point load transfer
Bearing capacity, founding depth, starter bar set-out
Strip footing
Load-bearing wall foundations, continuous load distribution
Width, depth, reinforcement, drainage
Pier footing
Deep founding where surface soils are inadequate
Bored pier diameter, founding level, reinforcement cage
Combined footing
Adjacent columns with overlapping influence zones
Load distribution, reinforcement detailing
Raft slab
Where uniform load distribution across the full footprint is required
AS 2870 compliance where applicable, ground preparation
Thickened edge footing
Slab perimeter support on commercial and industrial buildings
Edge load, reinforcement, setdown level

The process

How QCG Manages a Commercial Footing Scope

QCG manages every commercial footing scope as a defined, documented process — from drawings review and founding-level verification through to hold point sign-off and close-out documentation. The following is how a footing package is delivered from first enquiry to final handover.

Step 01: Enquiry and drawings review

Submit an enquiry with project details and structural drawings. QCG reviews the footing schedule and geotechnical requirements and responds within one business day. Footing scopes cannot be quoted without structural drawings. Preliminary discussions are available if drawings are in progress.

Step 02: Set-out and founding level review

Before any concrete is placed, QCG establishes the footing set-out from the structural drawings and verifies the excavated founding level matches the design assumption. Any discrepancy between the drawings and site conditions is reported to the structural engineer before work proceeds.

Step 03: Pre-pour inspection and hold point

Reinforcement, cover, starter bar positions, and anchor bolt set-out are inspected and documented. The hold point is signed off before concrete placement begins. If the hold point requires third-party attendance, QCG coordinates that as part of the programme.

Step 04: Concrete placement and documentation

Concrete is placed to the approved mix design and specification. Concrete test cylinders are taken on every commercial footing pour and submitted to a NATA-accredited laboratory in Brisbane or the Sunshine Coast. Placement is recorded including timing, batch quantities, and pour sequence.

Step 05: Close-out documentation

At completion, QCG provides founding level records, reinforcement inspection sign-offs, anchor bolt set-out records, and concrete test results. The close-out package is provided before QCG demobilises from site.

Right fit

What QCG Delivers on a Commercial Footing Scope

QCG manages commercial footing packages from excavation review through to concrete placement, starter bar and anchor bolt installation, and QA documentation. The following scope items are standard on QCG footing projects.

Excavation and preparation

Reinforcement

Formwork

Concrete placement

QA documentation

Need a footing contractor who works from the drawings and documents everything?

Who Engages QCG for Reinforced Footings

Right fit

Who QCG Works With on Commercial Footing Projects

Head Contractors

You need a footing subcontractor who works directly from structural drawings, completes hold point inspections without being prompted, and delivers documentation that matches your project’s QA requirements.

Commercial Builders

You are constructing a commercial building and need a footing contractor with the process discipline to get the foundations right before structure goes up.

Project Managers

You are managing programme on a commercial build where founding depth confirmation, hold point sign-offs, and anchor bolt set-out accuracy are critical to the structural programme above.

Developers

You are delivering a commercial development and want a single subcontractor managing reinforcement, formwork, and concrete for the footing package from one point of responsibility.

Need a footing contractor who works from the drawings and documents everything?

What makes QCG different

Why Head Contractors and Developers Choose QCG for Commercial Footings and Foundations

The footing stage of any commercial project is where the least visible work determines the most expensive outcomes. Getting it right is not about pouring concrete carefully. It is about reading the drawings correctly, verifying the founding conditions match the design assumptions, and completing the hold points before any concrete goes in the ground.

Engineering background that starts with the drawings

Civil engineer Anthony Quinn built QCG around a simple principle: the work that matters most on any project is the work that cannot be undone. Footings cannot be undone. Anthony’s 15+ years on Tier 1 infrastructure projects — where founding conditions, reinforcement tolerance, and engineering sign-off were audit items, not suggestions — shaped how QCG approaches every footing scope it takes on.

Anchor bolt and starter bar set-out is treated as precision work

Anchor bolt positions and starter bar projections are fixed in concrete. Once the pour is done, there is no adjusting them without core drilling, cutting, and re-grouting, which costs time and money no programme has room for. QCG treats set-out as precision work. Every anchor bolt and starter bar position is checked against the structural drawings and signed off before concrete placement begins.

Hold points are completed, not waived

Hold point inspections on footings exist because founding reinforcement is buried and cannot be inspected after the pour. QCG completes every required hold point inspection and produces the sign-off record before proceeding. If the hold point requires the structural engineer or project manager to attend, QCG coordinates that attendance as part of the programme.

Documentation that closes out the footing stage properly

Founding level records, reinforcement inspection sign-offs, concrete test results, and anchor bolt set-out records are produced as standard. The footing close-out package provides the project file with a complete record of what was built, at what depth, and to what specification.

Frequently Asked Questions About Commercial Footings

Do I need council approval for a concrete project in Queensland?

It depends on the type of work. Most standard residential concrete jobs do not require building approval, but a vehicle crossover connecting to a council-controlled road usually requires a permit from your local council, such as Sunshine Coast Council. Concrete slabs for new structures, sheds, or outbuildings may also require building approval depending on size and intended use. QCG will flag any approval requirements identified during scoping so you know before the job starts.

Some minor surface cracking in concrete over time is normal and does not affect structural integrity. Significant cracking within the first few years is almost always caused by inadequate base preparation, incorrect mix design, or missing reinforcement. A well-built concrete slab or structure on the Sunshine Coast can last 25 to 30 years or more with proper design and maintenance. QCG uses the correct concrete mix, properly placed steel reinforcement, and a controlled curing process to minimise cracking risk and give your concrete the best chance of reaching that lifespan.

A standard concreter typically provides labour for straightforward residential pours. A commercial concrete contractor like QCG brings engineering-level systems, full QA documentation including ITPs and SWMS, program management, and a director who is directly accountable for delivery. If your project requires documentation, compliance sign-off, or program certainty across the Sunshine Coast or South East Queensland, a standard concreter is not the right fit.

Most residential concrete jobs on the Sunshine Coast are completed in a single day depending on scope and access. Concrete is typically safe to walk on within 24 to 48 hours but should not carry vehicle traffic or heavy loads for at least 7 days. Full design strength is reached at 28 days. QCG will confirm the full curing timeline before the job starts so there are no surprises.

It depends on the project scope, classification, and specification requirements. For many commercial and civil concrete projects in Queensland, RPEQ engineering sign-off is required or strongly recommended to meet NCC and AS 2870 requirements, including Form 15 and Form 12 certification. QCG operates with an RPEQ engineering partnership, which means we can facilitate that requirement without you having to source a separate engineer and manage the interface yourself.

Residential concreting costs on the Sunshine Coast vary depending on the type of work, size, access, ground conditions, finish type, and reinforcement requirements. As a general guide, plain reinforced concrete work typically starts from around $80 to $130 per square metre, with exposed aggregate, decorative finishes, or more complex pours priced higher. The only way to get an accurate number for your specific job is a written quote after a proper site assessment. Contact QCG for a residential quote with no obligation.

As a minimum, most Tier 1 and Tier 2 head contractors require a current SWMS, an Inspection and Test Plan, cylinder and slump test records, reinforcement inspection sign-off, and public liability insurance at the required level. QCG produces all of this as standard on every commercial job. We do not need to be asked twice.

Accreditations and compliance

QBCC Licence

15606141

Public Liability Insurance

$20M

Workers Compensation

Current

AS 3600

All structural footings delivered in compliance with AS 3600 Concrete Structures

NCC compliance

Structural footing works delivered in coordination with RPEQ-registered engineers where required

NATA-accredited testing

Concrete test cylinders submitted to NATA-accredited laboratory on all footing scopes

ITP

Site-specific SWMS prepared for every footing project

Our Certifications

Master Builders Queensland logo with Proud Member badge.
RPEng logo for Registered Professional Engineer of Australia.
Queensland Building and Construction Commission logo with house icon.
ISO 9001:2015 certified company badge for quality management.
Blue fully insured badge with FJU Insurance text for service assurance.

Start the conversation

Submit a Commercial Footings Enquiry

All commercial enquiries are acknowledged within one business day. To get a response that is useful rather than generic, include project location, building type, footing type if known, number of footings or approximate scope, required start date, and whether structural drawings are available.

QCG delivers commercial footings and foundations across Brisbane, the Sunshine Coast, Gold Coast, Ipswich, Gympie, and wider South East Queensland.

What happens after you enquire:

  1. A senior QCG team member reviews your enquiry personally
  2. You receive an acknowledgement within one business day
  3. If your project is a fit, QCG follows up to discuss the structural drawings, founding conditions, and programme

Which of these do you need help with?

Would you prefer to have a call? Call us on 0458 564 155

Commercial Concrete Contractor Serving the Sunshine Coast and South East Queensland

Civil and Infrastructure Concrete Contractor Serving the Sunshine Coast and South East Queensland

Structural and Specialist Concrete Contractor Serving the Sunshine Coast and South East Queensland