Reinforced footings

Reinforced Footing Contractor Serving the Sunshine Coast and South East Queensland

Footings are buried the day after they are poured. By the time a problem surfaces, it is under a building. Quinn Civil Group installs reinforced strip, pad, and raft footings across SEQ, executed from structural drawings with documented hold point inspections on every pour.

15+

Years civil and structural concrete experience

$100M+

Infrastructure works exposure

Numerous

Reinforced footing packages completed

Zero

Lost Time Injuries under managed scope

About this service

What Reinforced Footings Involve and Why the Execution Matters

A reinforced footing is not a complicated element. It is a precisely specified one. The structural engineer has calculated the bearing capacity, the reinforcement required to transfer load, the concrete grade to achieve design strength, and the cover depth to protect the steel. None of those parameters are negotiable on site.

Where footing installations go wrong, it is rarely the concrete itself. It is the set-out not checked against drawings, the reinforcement not matching the schedule, the cover inconsistent, or the hold point signed off without a real inspection. A structure is then built on footings that do not match the design, and nobody finds out until something moves.

QCG installs reinforced footings as a structured scope. Set-out is confirmed against drawings before a bar is placed. Reinforcement is checked against the schedule before a hold point is called. Nothing is poured until the inspection is documented and signed off.

QCG delivers reinforced footing scopes across the Sunshine Coast, Brisbane, Gympie, Ipswich, and wider South East Queensland.

Footing Types

Reinforced Footing Types QCG Installs Across South East Queensland

Footing type

Relevant standard

Strip Footings

AS 3600, AS 2870

Pad Footings

AS 3600

Raft Footings

AS 3600, AS 2870

Thickened Edge Beams

AS 3600

Pier Footings

AS 3600

Footing type

Application and key design consideration

Strip Footings

Load-bearing walls, masonry construction, tilt-panel edges. Continuous reinforcement along full length, level base.

Pad Footings

Column bases, isolated structural loads. Set-out tolerance critical, reinforcement cage sizing.

Raft Footings

Poor subgrade conditions, uniform load distribution. Depth, reinforcement layout, edge beam detailing.

Thickened Edge Beams

Slab perimeters, transition to strip footing. Reinforcement continuity at slab-footing junction.

Pier Footings

Sloped sites, variable bearing conditions. Depth to competent bearing, cage alignment.

Footing type
Relevant standard
Application and key design consideration
Strip Footings
AS 3600, AS 2870
Load-bearing walls, masonry construction, tilt-panel edges. Continuous reinforcement along full length, level base.
Pad Footings
AS 3600
Column bases, isolated structural loads. Set-out tolerance critical, reinforcement cage sizing.
Raft Footings
AS 3600, AS 2870
Poor subgrade conditions, uniform load distribution. Depth, reinforcement layout, edge beam detailing.
Thickened Edge Beams
AS 3600
Slab perimeters, transition to strip footing. Reinforcement continuity at slab-footing junction.
Pier Footings
AS 3600
Sloped sites, variable bearing conditions. Depth to competent bearing, cage alignment.

The process

How QCG Manages a Reinforced Footing Scope

Step 01: Drawing review and scope assessment

Footing enquiries start with the structural drawings. QCG reviews footing layouts, reinforcement schedules, concrete grades, cover requirements, and set-out tolerances before providing a scope assessment. If drawings are not yet finalised, preliminary discussions can establish programme and scope parameters.

Step 02: Pricing from the structural specification

QCG prices reinforced footing scopes from the structural drawings, not a rate per square metre. The scope is written in plain terms. What is included, what is excluded, and what programme assumptions QCG is pricing against are all documented before the scope is signed off. Conflicts between the drawings and expected site conditions are flagged at this stage.

Step 03: Excavation check before reinforcement commences

Where QCG is not responsible for excavation, the finished excavation is checked for dimensions, base condition, and level before reinforcement work begins. If what is in the ground does not match the structural drawings, that conversation happens before a bar is placed, not after.

Step 04: Reinforcement installation and hold point

Reinforcement is installed to the structural schedule. Bar size, spacing, laps, cover, and end conditions are checked against the drawings. The hold point inspection is completed and documented before the pour proceeds.

Step 05: Concrete placement and curing

Concrete is placed to the specified grade and mix design. Curing is managed to AS 3600 requirements for the footing element type and ambient conditions.

Step 06: Documentation and close-out

At close-out, QCG hands over the full package without being asked. Pour records, reinforcement inspection records, concrete test results, and ITP sign-offs, plus RPEQ certification where required.

Is this page for you?

Who QCG Works With on Commercial Footing Projects

Structural Engineers

The footing is where your design meets the ground. You need a contractor who installs the reinforcement schedule you specified, holds the cover you required, and hands back documentation that confirms your design intent was executed. QCG works from your drawings as the non-negotiable reference on every scope.

Head Contractors

A footing scope that drags or misses hold point sign-offs backs up every trade above it. QCG manages the footing programme with the same attention to schedule as the pour itself, and does not leave your superintendent waiting on QA records at close-out.

Project Managers

You cannot afford a footing scope that generates RFIs, disputed variations, or hold point delays. QCG prices from the drawings and raises conflicts before mobilisation, not mid-scope when the programme is already running.

Developers

The footing is the foundation of your project’s structural integrity and your liability position. QCG provides the documentation that confirms the footing was installed to the engineering specification before the next stage begins.

Working on a project where footings are one element of a larger scope?

Who Engages QCG for Reinforced Footings

What sets us apart

Why Engineers and Head Contractors Choose QCG for Reinforced Footings

Set-out confirmed before a bar is placed

Footing set-out errors are the most common source of structural RFIs on commercial projects. QCG checks set-out against the structural drawings before reinforcement installation begins. Conflicts with the drawing are raised with the superintendent before they become a pour-day problem.

Reinforcement installed to schedule, not to habit

Every footing QCG installs is reinforced to the structural engineer’s schedule. Bar size, spacing, laps, and end anchorage are checked against the drawings before the hold point is called. Cover is measured and recorded, not estimated.

QCG does not call a hold point as a formality. The pre-pour inspection is a structured check of set-out, reinforcement, cover, formwork condition, and mix design. Once concrete is placed, what is underneath it is permanent. It is treated accordingly.

Documentation ready at close-out, not on request

The close-out package is ready before you ask for it. Every footing scope closes with pour records, reinforcement inspection sign-offs, concrete test results, and ITP records. It is waiting for the superintendent, not the other way around.

Frequently Asked Questions About Reinforced Footings

What is the difference between a strip footing and a pad footing?

A strip footing runs continuously under a load-bearing wall or tilt-panel edge, distributing load along its length. A pad footing sits under an isolated point load such as a column base, transferring that load to the bearing stratum directly below. The structural engineer specifies which type is required based on the structural system and subgrade conditions. QCG installs both to AS 3600 requirements.

Footing depth is determined by the structural engineer based on subgrade bearing capacity, design loads, and shrink-swell depth requirements. In South East Queensland, residential footings are typically designed to AS 2870. Commercial footings are governed by AS 3600 and the specific structural design. QCG does not determine footing depth. We install to the depth specified in the structural drawings.

Cover requirements depend on the exposure classification and concrete grade specified. In a standard commercial footing in SEQ cast against the ground, minimum cover is typically 75mm per AS 3600. QCG measures and records cover before every pour. It is not estimated or assumed.

Yes. QCG regularly delivers reinforced footings as part of a larger structural scope including ground beams and engineered slabs. Coordinating these elements under a single subcontractor removes the interface risk between footing and ground beam reinforcement continuity, and simplifies the ITP and hold point structure for the superintendent.

QCG checks set-out and excavation dimensions against the structural drawings before reinforcement installation begins. If the excavation does not match the drawing, QCG raises the discrepancy with the superintendent before proceeding. We do not install reinforcement into an excavation that does not match the structural specification.

Standing water in a footing excavation is not acceptable before a pour. If weather conditions are likely to affect placement quality or early curing, QCG advises the superintendent in advance and makes a recommendation on whether to proceed. The decision is made against the concrete specification requirements, not convenience.

Accreditations and compliance

QBCC Licence

15606141

Public Liability Insurance

$20M

Workers Compensation

Current

AS 3600

All reinforced footings executed to Australian Standards

NCC compliance

Structural verification and certification on applicable scopes

NATA-accredited testing

ITPs and SWMS on every scope

ITP

Director Anthony Quinn

Our Certifications

Master Builders Queensland logo with Proud Member badge.
RPEng logo for Registered Professional Engineer of Australia.
Queensland Building and Construction Commission logo with house icon.
ISO 9001:2015 certified company badge for quality management.
Blue fully insured badge with FJU Insurance text for service assurance.

Start the conversation

Got Drawings? Let's Talk About Your Footing Scope.

Send through your structural drawings and project details. QCG will review the footing layout, reinforcement schedule, and programme requirements and respond within one business day.

If drawings are still in progress, reach out now to discuss scope and timeline. Early engagement means fewer surprises when the programme starts moving.

Which of these do you need help with?

Would you prefer to have a call? Call us on 0458 564 155

Commercial Concrete Contractor Serving the Sunshine Coast and South East Queensland